Point Load Test Conducted by IIT - Hyd

  • What we propose: The use of STARK STEEL as Reinforcement , by REPLACING the conventional TMT Bars, Steel Fibres, Weld Mesh with our STARK STEEL Rods
  • STARK STEEL can be used as Reinforcement for CONCRETE FLOOR SLABS as per TR 34 4th Edition or IS 456 Standards
  • Tests Conducted: Four slabs each of size 1mtr x 1mtr x 170mm & 1mtr x 1mtr x 150mm were casted. We subject the Concrete Slabs to PUNCHING / POINT LOAD testing method. The tests were conducted at IIT Hyderabad under the supervision of the respected Dr . S. SURIYA PRAKASH, Professor Dept. of Civil Engineering, IIT Hyderabad. The results were;
Punching Shear Test Set Up
Specimen 1: Slab Dimensions – 1000mm x 1000mm x 170mm, Grade of Concrete – M25, STARK STEEL Spacing – 150mm c/c, Cover from bottom – 40mm

Failure mode of the specimen D170_S150

(D means depth and S means spacing of Stark Steel rebar)
Sl. No. SAMPLE SPECIFICATION CRACKING LOAD (Mt) ULTIMATE LOAD (Mt)
1. D170_S150 11.290 19.730
Specimen 2: Slab Dimensions – 1000mm x 1000mm x 170mm, Grade of Concrete – M25 STARK STEEL Spacing – 200mm c/c, Cover from bottom – 40mm

Failure mode of the specimen D170_S200

(D means depth and S means spacing of Stark Steel rebar)
Sl. No. SAMPLE SPECIFICATION CRACKING LOAD (Mt) ULTIMATE LOAD (Mt)
1. D170_S200 10.490 15.230
Specimen 3: Slab Dimensions – 1000mm x 1000mm x 150mm, Grade of Concrete – M25 STARK STEEL Spacing – 150mm c/c, Cover from bottom – 40mm

Failure mode of the specimen D150_S150

(D means depth and S means spacing of Stark Steel rebar)
Sl. No. SAMPLE SPECIFICATION CRACKING LOAD (Mt) ULTIMATE LOAD (Mt)
1. D150_S150 8.180 17.780
Specimen 4: Slab Dimensions – 1000mm x 1000mm x 150mm, Grade of Concrete – M25 STARK STEEL Spacing – 200mm c/c, Cover from bottom – 40mm

Failure mode of the specimen D150_S200

(D means depth and S means spacing of Stark Steel rebar)
Sl. No. SAMPLE SPECIFICATION CRACKING LOAD (Mt) ULTIMATE LOAD (Mt)